<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:series="http://unfoldingneurons.com/"
	xmlns:itunes="http://www.itunes.com/dtds/podcast-1.0.dtd"
xmlns:rawvoice="http://www.rawvoice.com/rawvoiceRssModule/"
>

<channel>
	<title>Gestalt IT &#187; Dynamic Cache Partitioning Archives  &#8211; Gestalt IT</title>
	<atom:link href="http://gestaltit.com/tag/dynamic-cache-partitioning/feed/" rel="self" type="application/rss+xml" />
	<link>http://gestaltit.com</link>
	<description>Independent Experts United</description>
	<lastBuildDate>Wed, 08 Feb 2012 17:00:34 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
<image>
			<title>Gestalt IT</title>
			<url>http://gestaltit.com/wp-content/uploads/2009/02/gestalt-it-feedicon-21.png</url>
			<link>http://gestaltit.com</link>
			<width>144</width>
			<height>37</height>
			<description>Independent Experts United</description>
		</image><!-- podcast_generator="Blubrry PowerPress/2.0.4" -->
	<itunes:summary>Gestalt IT is a community of independent IT infrastructure experts. We gather at GestaltIT.com and our Tech FIeld Day events to discuss the topics of the day. This podcast includes video and audio recordings of these discussions.</itunes:summary>
	<itunes:author>Stephen Foskett</itunes:author>
	<itunes:explicit>no</itunes:explicit>
	<itunes:image href="http://gestaltit.com/wp-content/uploads/powerpress/Gestalt_IT_Tech_Field_Day_Roundtable_Podcast_600.png" />
	<itunes:owner>
		<itunes:name>Stephen Foskett</itunes:name>
		<itunes:email>stephen@fosketts.net</itunes:email>
	</itunes:owner>
	<managingEditor>stephen@fosketts.net (Stephen Foskett)</managingEditor>
	<itunes:subtitle>The best independent IT commentary</itunes:subtitle>
	<itunes:keywords>Storage, Virtualization, Networking, IT</itunes:keywords>
	<image>
		<title>Gestalt IT &#187; Dynamic Cache Partitioning Archives  &#8211; Gestalt IT</title>
		<url>http://gestaltit.com/wp-content/uploads/powerpress/Gestalt_IT_Tech_Field_Day_Roundtable_Podcast_144.png</url>
		<link>http://gestaltit.com</link>
	</image>
	<itunes:category text="Technology" />
	<itunes:category text="Business" />
	<itunes:category text="Technology">
		<itunes:category text="Tech News" />
	</itunes:category>
<atom:link rel="hub" href="http://pubsubhubbub.appspot.com" />
	<atom:link rel="hub" href="http://superfeedr.com/hubbub" />
			<item>
		<title>After all, FAST makes a debut</title>
		<link>http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/</link>
		<comments>http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/#comments</comments>
		<pubDate>Thu, 10 Dec 2009 18:00:26 +0000</pubDate>
		<dc:creator>Devang Panchigar</dc:creator>
				<category><![CDATA[Storage]]></category>
		<category><![CDATA[Tech]]></category>
		<category><![CDATA[5874]]></category>
		<category><![CDATA[Atmos]]></category>
		<category><![CDATA[Automated]]></category>
		<category><![CDATA[Celerra]]></category>
		<category><![CDATA[Centera]]></category>
		<category><![CDATA[CLARiiON]]></category>
		<category><![CDATA[CLI]]></category>
		<category><![CDATA[CX4]]></category>
		<category><![CDATA[Data Movement]]></category>
		<category><![CDATA[Dynamic Cache Partitioning]]></category>
		<category><![CDATA[EMC]]></category>
		<category><![CDATA[FAST]]></category>
		<category><![CDATA[Fibre]]></category>
		<category><![CDATA[flash]]></category>
		<category><![CDATA[Fully Automated Storage Tiering]]></category>
		<category><![CDATA[Navisphere Analyzer]]></category>
		<category><![CDATA[Navisphere Quality Service manager]]></category>
		<category><![CDATA[NS]]></category>
		<category><![CDATA[Rainfinity file management / VE]]></category>
		<category><![CDATA[Rainfinity File management appliance]]></category>
		<category><![CDATA[Release 29]]></category>
		<category><![CDATA[SATA]]></category>
		<category><![CDATA[SSD]]></category>
		<category><![CDATA[Symcli]]></category>
		<category><![CDATA[Symmetrix Management Console]]></category>
		<category><![CDATA[Symmetrix Optimizer]]></category>
		<category><![CDATA[symmetrix performance analyzer]]></category>
		<category><![CDATA[symmetrix priority controls]]></category>
		<category><![CDATA[V-Max]]></category>

		<guid isPermaLink="false">http://gestaltit.com/?p=1940</guid>
		<description><![CDATA[Truly this was one of the most awaited products of 2009 from EMC after the initial announcement by EMC back in April 2009 along with the release of Symmetrix V-Max. Along with FAST, EMC has also introduced some new enhancements to the EMC Symmetrix V-Max, Clariion CX4 and Celerra NS platforms. Currently FAST will be available on the above 3 platforms at debut and will provide automated storage tiering “in-the-box” for Symmetrix V-Max, “in-the-box” for Clariion CX4 and “out-of-box” for Celerra NS platforms.]]></description>
			<content:encoded><![CDATA[<p><strong> </strong></p>
<p>So EMC has proved critics like me wrong and have introduced EMC <strong>FAST (Fully Automated Storage Tiering)</strong> as an offering in Dec 2009. There were many skeptics like me that saw this product release being stalled because of various reasons, <a href="../2009/12/03/fast-miles-and-miles-away/">here.</a></p>
<p><strong> </strong></p>
<div class="mceIEcenter">
<dl>
<dt><strong><strong><a href="http://storagenerve.com/wp-content/uploads/2009/12/FAST.jpg" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/FAST.jpg" alt="FAST (Fully Automated Storage Tiering)" width="229" height="240" /></a></strong></strong></dt>
<dd>FAST (Fully Automated Storage Tiering)</dd>
</dl>
</div>
<p><strong> </strong></p>
<p>Truly this was one of the most awaited products of 2009 from EMC after the initial announcement by EMC back in April 2009 along with the release of Symmetrix V-Max.</p>
<p>I have dedicated a separate deep-dive section for EMC FAST on the StorageNerve Blog, <a href="../deepdive/emc/fast/">here</a></p>
<p>Along with FAST, EMC has also introduced some new<strong> </strong>enhancements<strong> </strong>to the EMC Symmetrix V-Max, Clariion CX4 and Celerra NS platforms. Currently FAST will be available on the above 3 platforms at debut and will provide automated storage tiering <strong>“in-the-box” </strong>for Symmetrix V-Max, <strong>“in-the-box”</strong> for Clariion CX4 and <strong>“out-of-box”</strong> for Celerra NS platforms.</p>
<p>As expected EMC has not made this feature free but rather offers a pricing model based on bundled software. FAST will be an available feature within <strong>ATSM: Advanced Tiering Storage Management</strong> bundle and will be charged based on <strong>RAW Capacity of the Array</strong> (Symmetrix, Clariion and Celerra)</p>
<p>FAST will not be supported on EMC DMX-4 and Clariion CX3. In essence FAST is only compatible with <strong>EMC Symmetrix V-Max Enginuity Microcode 5874.xxx.xxx</strong> and<strong> Clariion CX4 Flarecode Release 29</strong>.</p>
<p>FAST is a software only feature and integrates with existing hardware / software on the associated platforms.</p>
<p>The following are some of the features FAST will support at GA on the EMC Symmetrix V-Max, Clariion CX4 and Celerra NS platforms.</p>
<p><strong>EMC Symmetrix V-Max</strong></p>
<p><strong> </strong></p>
<p style="text-align: center">
<div class="mceIEcenter">
<dl>
<dt><a href="http://storagenerve.com/wp-content/uploads/2009/12/V-Max-data-movement.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/V-Max-data-movement-231x300.png" alt="Symmetrix V-Max Data Movement" width="231" height="300" /></a></dt>
<dd>Symmetrix V-Max Data Movement</dd>
</dl>
</div>
<p><strong> </strong></p>
<ul>
<li>Volume / LUN based data movement (Automated Storage Tiering) for open systems and CKD &#8211; mainframe volumes.</li>
</ul>
<ul>
<li>Management of FAST through Symmetrix Management Console or SymCLI</li>
</ul>
<ul>
<li>Data Movement can be accomplished between FLASH, fibre channel and SATA drives within the V-Max platform. Data can move in any direction and on any type of the drives based on policy.</li>
</ul>
<ul>
<li>Data movement within a single frame or serial number only.</li>
</ul>
<ul>
<li>FAST suite can be purchased as a standalone software suite but will be available at a discounted price based on a bundled option with Symmetrix Optimizer, DCP: Dynamic Cache Partitioning and SPC: Symmetrix Priority Controls.</li>
</ul>
<ul>
<li>Symmetrix Performance Analyzer is not required for FAST to operate on the Symmetrix V-Max platform. <span style="text-decoration: line-through"><br />
</span></li>
</ul>
<p><strong>EMC Clariion CX4</strong></p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<div class="mceIEcenter">
<dl>
<dt><strong><strong><a href="http://storagenerve.com/wp-content/uploads/2009/12/Clariion-data-movement.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/Clariion-data-movement-144x300.png" alt="Clariion CX4 Data Movement" width="144" height="300" /></a></strong></strong></dt>
<dd>Clariion CX4 Data Movement</dd>
</dl>
</div>
<p><strong> </strong></p>
<ul>
<li>LUN based data movement (Automated Storage Tiering)</li>
</ul>
<ul>
<li>Management of FAST will be enabled through CLI only. Not supported as an integrated part of Navisphere today.</li>
</ul>
<ul>
<li>Will work with Flarecode Release 29 (Clariion CX4) only.</li>
</ul>
<ul>
<li>Unlike the Symmetrix, the automated data movement will only be supported between fibre channel drives to FLASH or fibre channel drives to SATA. There is no automation related to data movement from FLASH to fibre channel or FLASH to SATA or SATA to FLASH or SATA to fibre Channel drives.</li>
</ul>
<ul>
<li>Data movement within a single frame or serial number only.</li>
</ul>
<ul>
<li>FAST suite can be purchased as a standalone software suite but will be available at a discounted price based on bundled option with Navisphere Analyzer and NQSM: Navisphere Quality Service Manager.</li>
</ul>
<ul>
<li>Navisphere Analyzer is required for FAST to operate.</li>
</ul>
<p><strong>EMC Celerra platform</strong></p>
<p><strong> </strong></p>
<div class="mceIEcenter">
<dl>
<dt><strong><strong><a href="http://storagenerve.com/wp-content/uploads/2009/12/Celerra-in-box-movement.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/Celerra-in-box-movement-121x300.png" alt="Celerra in the box data movement" width="121" height="300" /></a></strong></strong></dt>
<dd>Celerra in the box data movement</dd>
</dl>
</div>
<p><strong> </strong></p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<div class="mceIEcenter">
<dl>
<dt><strong><strong><a href="http://storagenerve.com/wp-content/uploads/2009/12/Celerra-out-of-box-movement.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/Celerra-out-of-box-movement-300x288.png" alt="Celerra in the box and out of box data movement" width="300" height="288" /></a></strong></strong></dt>
<dd>Celerra out of box data movement</dd>
</dl>
</div>
<p><strong> </strong></p>
<ul>
<li>File based data movement (Automated Storage Tiering)</li>
</ul>
<ul>
<li>Management of FAST can be accomplished through Rainfinity file management appliance GUI or CLI. Customers also have an option to purchase Rainfinity File management/VE (Virtual Appliance), which has some limitations.</li>
</ul>
<ul>
<li>Data movement can be enabled to another tier “in-the-box” or to another Celerra or Centera or Atmos.</li>
</ul>
<ul>
<li>Celerra FAST is most interesting as it enables out the system data movement, like to another Celerra or Centera or Atmos.</li>
</ul>
<ul>
<li>FAST suite can be purchased as a standalone software suite but will be available at a discounted price based on a bundled option with Rainfinity File Management Appliance or Rainfinity File Management /VE.</li>
</ul>
<p>Based on EMC heat index charts, a before and after picture of a FAST implementation would look like this.</p>
<div class="mceIEcenter">
<dl>
<dt><a href="http://storagenerve.com/wp-content/uploads/2009/12/FAST-implementation1.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/FAST-implementation1.png" alt="FAST Implementation" width="544" height="190" /></a></dt>
<dd>FAST Implementation</dd>
</dl>
</div>
<p><strong>A FAST implementation video</strong></p>
<p style="text-align: center">
<p style="text-align: center">
<p>Here is a <a href="http://gestaltit.com/featured/top/gestalt/emc-unified-platform-storage-tiering/" >post</a>, back from August 2009 on Gestalt IT describing how EMC’s Unified Storage vision and federation may work. It is good to see, some of those things come to fruition now, and at least FAST with Celerra proves it.</p>
<p>Stay tuned for a series of FAST posts over the next few days talking about various other topics and how FAST plays within those areas.</p>
<div id="crp_related"><h3>You might also want to read these other posts...</h3><ul><li><a href="http://gestaltit.com/all/tech/storage/devang/fast-features-drawbacks-applications-and-some-questions/"  rel="bookmark" class="crp_title">FAST: Features, Drawbacks, Applications and some Questions</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/enhancements-emc-symmetrix-vmax-systems-coming/"  rel="bookmark" class="crp_title">Enhancements to EMC Symmetrix V-Max Systems coming!!</a></li><li><a href="http://gestaltit.com/featured/top/gestalt/emc-unified-platform-storage-tiering/"  rel="bookmark" class="crp_title">EMC’s Unified Platform and Storage Tiering</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/emc-symmetrix-vmax-supported-drive-type/"  rel="bookmark" class="crp_title">EMC Symmetrix V-Max: Supported drive type</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/symmetrix-file-system-sfs/"  rel="bookmark" class="crp_title">Symmetrix File System (SFS)</a></li></ul></div><script src="http://feeds.feedburner.com/~s/sfoskett?i=http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/" type="text/javascript" charset="utf-8"></script><hr />
<p><small>© Devang for <a href="http://gestaltit.com">Gestalt IT</a>, 2009. |
<a href="http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/">After all, FAST makes a debut</a>
<br/>
Read more posts categorized as <a href="http://gestaltit.com/category/all/tech/storage/" title="View all posts in Storage" rel="category tag">Storage</a>, <a href="http://gestaltit.com/category/all/tech/" title="View all posts in Tech" rel="category tag">Tech</a><br/>
</small></p>]]></content:encoded>
			<wfw:commentRss>http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>