<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:series="http://unfoldingneurons.com/"
	xmlns:itunes="http://www.itunes.com/dtds/podcast-1.0.dtd"
xmlns:rawvoice="http://www.rawvoice.com/rawvoiceRssModule/"
>

<channel>
	<title>Gestalt IT &#187; Navisphere Analyzer Archives  &#8211; Gestalt IT</title>
	<atom:link href="http://gestaltit.com/tag/navisphere-analyzer/feed/" rel="self" type="application/rss+xml" />
	<link>http://gestaltit.com</link>
	<description>Independent Experts United</description>
	<lastBuildDate>Sat, 26 May 2012 00:43:58 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.2</generator>
<image>
			<title>Gestalt IT</title>
			<url>http://gestaltit.com/wp-content/uploads/2009/02/gestalt-it-feedicon-21.png</url>
			<link>http://gestaltit.com</link>
			<width>144</width>
			<height>37</height>
			<description>Independent Experts United</description>
		</image><!-- podcast_generator="Blubrry PowerPress/4.0" -->
	<itunes:summary>Gestalt IT is a community of independent IT infrastructure experts. We gather at GestaltIT.com and our Tech FIeld Day events to discuss the topics of the day. This podcast includes video and audio recordings of these discussions.</itunes:summary>
	<itunes:author>Stephen Foskett</itunes:author>
	<itunes:explicit>no</itunes:explicit>
	<itunes:image href="http://gestaltit.com/wp-content/uploads/powerpress/Gestalt_IT_Tech_Field_Day_Roundtable_Podcast_600.png" />
	<itunes:owner>
		<itunes:name>Stephen Foskett</itunes:name>
		<itunes:email>stephen@fosketts.net</itunes:email>
	</itunes:owner>
	<managingEditor>stephen@fosketts.net (Stephen Foskett)</managingEditor>
	<itunes:subtitle>The best independent IT commentary</itunes:subtitle>
	<itunes:keywords>Storage, Virtualization, Networking, IT</itunes:keywords>
	<image>
		<title>Gestalt IT &#187; Navisphere Analyzer Archives  &#8211; Gestalt IT</title>
		<url>http://gestaltit.com/wp-content/uploads/powerpress/Gestalt_IT_Tech_Field_Day_Roundtable_Podcast_144.png</url>
		<link>http://gestaltit.com</link>
	</image>
	<itunes:category text="Technology" />
	<itunes:category text="Business" />
	<itunes:category text="Technology">
		<itunes:category text="Tech News" />
	</itunes:category>
<atom:link rel="hub" href="http://pubsubhubbub.appspot.com" />
	<atom:link rel="hub" href="http://superfeedr.com/hubbub" />
			<item>
		<title>FAST: Features, Drawbacks, Applications and some Questions</title>
		<link>http://gestaltit.com/all/tech/storage/devang/fast-features-drawbacks-applications-and-some-questions/</link>
		<comments>http://gestaltit.com/all/tech/storage/devang/fast-features-drawbacks-applications-and-some-questions/#comments</comments>
		<pubDate>Fri, 11 Dec 2009 18:00:19 +0000</pubDate>
		<dc:creator>Devang Panchigar</dc:creator>
				<category><![CDATA[Storage]]></category>
		<category><![CDATA["in-the-box"]]></category>
		<category><![CDATA["out-of-box"]]></category>
		<category><![CDATA[5874]]></category>
		<category><![CDATA[Advanced Tiering Storage management]]></category>
		<category><![CDATA[Atmos]]></category>
		<category><![CDATA[ATSM]]></category>
		<category><![CDATA[average I/O]]></category>
		<category><![CDATA[Celerra NS]]></category>
		<category><![CDATA[Centera]]></category>
		<category><![CDATA[CKD]]></category>
		<category><![CDATA[CLARiiON]]></category>
		<category><![CDATA[configuration]]></category>
		<category><![CDATA[CX4]]></category>
		<category><![CDATA[Data center]]></category>
		<category><![CDATA[Drives]]></category>
		<category><![CDATA[FAST]]></category>
		<category><![CDATA[FAST LUN Migrator]]></category>
		<category><![CDATA[FBA]]></category>
		<category><![CDATA[Fibre]]></category>
		<category><![CDATA[flash]]></category>
		<category><![CDATA[Fully Automated Storage Tiering]]></category>
		<category><![CDATA[IOPS]]></category>
		<category><![CDATA[LUN]]></category>
		<category><![CDATA[Mainframe]]></category>
		<category><![CDATA[multitenancy]]></category>
		<category><![CDATA[Naviseccli]]></category>
		<category><![CDATA[Navisphere Analyzer]]></category>
		<category><![CDATA[Open Systems]]></category>
		<category><![CDATA[policy]]></category>
		<category><![CDATA[Private Clouds]]></category>
		<category><![CDATA[Rainfinity file management / VE]]></category>
		<category><![CDATA[Rainfinity File management appliance]]></category>
		<category><![CDATA[Raw capacity]]></category>
		<category><![CDATA[Release 29]]></category>
		<category><![CDATA[SATA]]></category>
		<category><![CDATA[SLA]]></category>
		<category><![CDATA[storage groups]]></category>
		<category><![CDATA[Symcli]]></category>
		<category><![CDATA[Symmetrix Management Console]]></category>
		<category><![CDATA[Symmetrix V-Max Thick provisioning]]></category>
		<category><![CDATA[vblock]]></category>
		<category><![CDATA[virtual provisioning]]></category>

		<guid isPermaLink="false">http://gestaltit.com/?p=1945</guid>
		<description><![CDATA[FAST (FULLY AUTOMATED STORAGE TIERING). FAST made a debut in the storage market yesterday (12/08/09). Finally after the market buzz we got a preview of the product in terms of its features, functionality, characteristics, possible shortcomings and use cases. This blog post focuses on the features, the drawbacks and some applications around FAST.  By no means is this a comprehensive or an exhaustive list of the above.]]></description>
			<content:encoded><![CDATA[<p><strong> </strong></p>
<p><strong>FAST (FULLY AUTOMATED STORAGE TIERING)</strong></p>
<p><strong> </strong></p>
<p>FAST made a debut in the storage market yesterday (12/08/09). Finally after the market buzz we got a preview of the product in terms of its features, functionality, characteristics, possible shortcomings and use cases.</p>
<p>This blog post focuses on the features, the drawbacks and some applications around FAST.  By no means is this a comprehensive or an exhaustive list of the above.</p>
<p><a href="../2009/12/08/after-all-fast-makes-a-debut/">After all, FAST makes a debut</a>, (The previous post on FAST).</p>
<p><span style="color: #ffffff">..</span></p>
<p style="text-align: center">
<div class="mceIEcenter">
<dl>
<dt><a href="http://storagenerve.com/wp-content/uploads/2009/12/emcfast.jpg" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/emcfast.jpg" alt="Imagine the possibilities of FAST with this infrastructure" width="451" height="337" /></a></dt>
<dd>Imagine the possibilities of FAST with this infrastructure</dd>
</dl>
</div>
<p style="text-align: center">NOTE: Out of the box thinking by EMC, imagine the flexibility one would have with a large infrastructure and FAST moving data based on policy. Its all about the big picture.</p>
<p><span style="color: #ffffff">..<br />
</span></p>
<p><span style="color: #ffffff">..</span></p>
<p><strong>Here are some features, highlights of FAST and how it operates. </strong></p>
<ul>
<li>FAST will perform data movement based on IOPS, average I/O size and write percentage. This is currently true for the Symmetrix V-Max, Clariion CX4 and Celerra NS.</li>
</ul>
<ul>
<li>Three elements that define FAST: Storage Type, FAST policies and Storage Groups.</li>
</ul>
<ul>
<li>FAST is based on user defined &#8211; configuration policies.</li>
</ul>
<ul>
<li>The configuration of FAST is typically done through FAST wizards (Symmetrix Management Console) on Symmetrix V-Max, FAST LUN Migrator for Clariion CX4 and Rainfinity File Management Appliance or VE for Celerra NS.</li>
</ul>
<p style="text-align: center"><a href="http://storagenerve.com/wp-content/uploads/2009/12/How-Fast-works-1.png" ><img class="aligncenter" src="http://storagenerve.com/wp-content/uploads/2009/12/How-Fast-works-1-300x135.png" alt="How Fast works 1" width="300" height="135" /></a></p>
<p style="text-align: center"><span style="color: #ffffff">..</span><a href="http://storagenerve.com/wp-content/uploads/2009/12/How-Fast-works-2.png" ><img class="aligncenter" src="http://storagenerve.com/wp-content/uploads/2009/12/How-Fast-works-2.png" alt="How Fast works 2" width="267" height="168" /></a><span style="color: #ffffff">..</span></p>
<p style="text-align: center"><a href="http://storagenerve.com/wp-content/uploads/2009/12/How-fast-works-3.png" ><img class="aligncenter" src="http://storagenerve.com/wp-content/uploads/2009/12/How-fast-works-3.png" alt="How fast works 3" width="280" height="176" /></a><span style="color: #ffffff">..</span></p>
<p style="text-align: center"><a href="http://storagenerve.com/wp-content/uploads/2009/12/Screen-shot-2009-12-08-at-5.13.31-PM.png" ><img class="aligncenter" src="http://storagenerve.com/wp-content/uploads/2009/12/Screen-shot-2009-12-08-at-5.13.31-PM-300x160.png" alt="Screen shot 2009-12-08 at 5.13.31 PM" width="300" height="160" /></a><span style="color: #ffffff">..</span></p>
<ul>
<li>User defined analysis period for FAST. That will enable FAST to recommend or perform data analysis and then a data move based on policy.</li>
</ul>
<ul>
<li>FAST created policies will associate with Storage Groups.</li>
</ul>
<ul>
<li>FAST policies will be configurable at a LUN / drive / drive type / speed etc level.</li>
</ul>
<ul>
<li>Data movement will take place based on a time of the date policy called “COLD” move or on usage policy called “HOT&#8221; move.</li>
</ul>
<ul>
<li>Data movement will take place between various drive types, various LUN types and LUN sizes. (LUN types, LUN sizes will need to be same for the source and destination LUNs). For example a 9GB FBA LUN being migrated from Fibre to FLASH will need similar source and destination LUN properties.</li>
</ul>
<ul>
<li>FAST data analysis will be performed in the background.</li>
</ul>
<ul>
<li>For Symmetrix V-Max platform FAST will perform all analysis without the use of Symmetrix Performance Analyzer. Understanding is there will be some sort of API plugin available on the Service Processor of the V-Max that will enable Symmetrix Management Console (FAST plugin) to interface with the Symmetrix through the SYMAPI interface.</li>
</ul>
<ul>
<li>For Clariions, the performance data of the array will be monitored and collected by Navisphere Analyzer.</li>
</ul>
<ul>
<li>Based on the source LUN analysis, FAST will recommend the user to move the data either a faster speed drives or a slower speed drives.</li>
</ul>
<ul>
<li>FAST will enable roll back based on user preferences (automated).</li>
</ul>
<ul>
<li>FAST will be configurable by Symmetrix Management console wizards or SYMCLI</li>
</ul>
<ul>
<li>FAST configurable by Clariion Naviseccli and installed on a host connected to Clariion, Host software called FAST LUN Migrator.</li>
</ul>
<ul>
<li>FAST configurable by Rainfinity File Management Appliance GUI or CLI for Celerra NS “out-of-box data” movement. This enables the Celerra to move data to another Celerra or Centera or Atmos.</li>
</ul>
<ul>
<li>FAST configurable by Rainfinity File Management / VE (Virtual Appliance) for Celerra NS “in-the-box” data movement.</li>
</ul>
<ul>
<li>FAST can be installed non-disruptively on all platforms.</li>
</ul>
<ul>
<li>FAST will operate both at an FBA and CKD level supporting open systems and mainframes for V-Max.</li>
</ul>
<ul>
<li>FAST will operate at a LUN level on Symmetrix V-Max</li>
</ul>
<ul>
<li>FAST will operate at a LUN level on Clariion CX4</li>
</ul>
<ul>
<li>FAST will operate at a file level on Celerra NS</li>
</ul>
<ul>
<li>FAST v1 users will be able to purchase a FAST v2 upgrade when it’s released in second half of 2010.</li>
</ul>
<ul>
<li>FAST can be purchased as a FAST suite or part of an ATSM (Advanced Tiering Storage Management) suite with bundled discounting prices.</li>
</ul>
<ul>
<li>For a unified storage system like a front end NAS (Celerra) with a backend SAN (Clariion), FAST can coexists at both levels. But it is not recommended to deploy FAST at a Celerra LUN level.</li>
</ul>
<ul>
<li>FAST integrates with Symmetrix Management Console and with Rainfinity GUI (Celerra) for simple management. Though Clariion implementation will need one to specialize in CLI.</li>
</ul>
<p><span style="color: #ffffff">.</span></p>
<p><strong> </strong></p>
<p style="text-align: center"><strong>FAST introduction by EMC</strong></p>
<p><strong> </strong></p>
<p align="center">
<p><strong> </strong></p>
<p><span style="color: #ffffff">..<br />
</span></p>
<p><span style="color: #ffffff">..</span></p>
<p><strong>FAST Drawbacks</strong></p>
<p>Here are some drawbacks of FAST as I see it today.</p>
<ul>
<li>Does not support Virtual provisioning. So the Virtual provisioned LUNs will not be FAST enabled. Sub-LUN expected in second half of 2010</li>
</ul>
<ul>
<li>FAST is not free and is charged based on RAW CAPACITY of the Storage Array.</li>
</ul>
<ul>
<li>FAST will only work with similar LUN types (example FBA LUNs can be migrated to FBA) and LUN sizes (9GB LUN can be migrated to a 9GB LUN) only.</li>
</ul>
<ul>
<li>FAST will require Professional Services and is not recommended for customer self implementation at least for the Clariion and the Celerra platforms. EMC is making a claim that FAST can be self provisioned on the Symmetrix V-Max platform.</li>
</ul>
<ul>
<li> FAST works only on current generation systems like EMC V-Max Enginuity 5874, Clariion CX4 Release 29 and Celerra NS.</li>
</ul>
<ul>
<li>With Clariion CX4 and FAST implementation, requirement is to have Navisphere Analyzer.</li>
</ul>
<ul>
<li>With Celerra NS and FAST implementation, requirement is to have Rainfinity File Management /VE or Appliance.</li>
</ul>
<ul>
<li>With Symmetrix V-Max FAST implementation, requirement is to have Symmetrix Management Console (Not free any more starting with the V-Max)</li>
</ul>
<ul>
<li>For the Clariions, FAST only analyzes Fibre drives and LUN movement has to initiate from Fibre channel to FLASH or Fibre channel to SATA drives only. Movement from FLASH to Fibre or SATA to Fibre has to be initiated manually.</li>
</ul>
<ul>
<li>A customer implementing Virtual Provisioning on Clariion CX4 and Symmetrix V-Max that is using 50% Thick Provisioning and 50% Virtual Provisioning. FAST will not work with Virtual Provisioned LUNs. But the customer will probably pay for 100% of Storage Raw Capacity when it comes to paying for FAST either non-bundled or bundled in an ATSM (Advanced Tiering Storage Management).</li>
</ul>
<ul>
<li>FAST does not support IBM System I platform currently.</li>
</ul>
<p><span style="color: #ffffff">..<br />
</span></p>
<p><span style="color: #ffffff">..</span></p>
<p><strong>Some real world FAST applications</strong></p>
<p><strong> </strong></p>
<div class="mceIEcenter">
<dl>
<dt><strong><strong><a href="http://storagenerve.com/wp-content/uploads/2009/12/vblock.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/vblock-300x225.png" alt="vBlock" width="300" height="225" /></a></strong></strong></dt>
<dd>vBlock</dd>
</dl>
</div>
<p><strong> </strong></p>
<p><strong> </strong></p>
<ul>
<li>Acadia Service Model can now add granularity with offerings around on-demand resources using FAST at its core.</li>
</ul>
<ul>
<li>On Demand application and workload needs can be met for OLTP, Data Warehousing, Mainframe compute and Virtual compute using FAST driven policies.</li>
</ul>
<ul>
<li>Multi-tenancy with Private Clouds</li>
</ul>
<ul>
<li>Move high demand data on faster drives while rarely used data goes on slower drives.</li>
</ul>
<ul>
<li>Sell ITaaS based on SLA’s. Higher SLA’s can mean higher price. All automated processes controlled by policy.</li>
</ul>
<ul>
<li>Higher transactions typically mean low overall cost; mean higher efficiency means higher profits all achievable through FAST policy engine.</li>
</ul>
<p>Need to see some real world implementations of FAST now. In theory and on paper, FAST looks pretty compelling but practically will it do the magic.</p>
<p><span style="color: #ffffff">..<br />
</span></p>
<p><span style="color: #ffffff">..</span></p>
<p><strong>Some unanswered questions today</strong></p>
<ul>
<li>How does it prevent from LUNs jumping between Fiber, FLASH and SATA if the application has un-expected performance that day?</li>
</ul>
<ul>
<li>Manageability of FAST interfaces.</li>
</ul>
<ul>
<li>Usability of FAST interfaces.</li>
</ul>
<ul>
<li>Granular configuration policies associated with analysis.</li>
</ul>
<ul>
<li>Future upgrades.</li>
</ul>
<ul>
<li>Current implementations and how long and how effective are those.</li>
</ul>
<ul>
<li>Can you improve performance without using SSD’s. Example with Fibre and SATA drives only.</li>
</ul>
<ul>
<li>With future upgrades from FAST v1 to FAST v2 what happens with current user defined policies.</li>
</ul>
<ul>
<li>Would Symcli scripts change with FAST implementation?</li>
</ul>
<ul>
<li>During lockout periods (Where Symmetrix configuration cannot change, eg before a BIN file change) would FAST still operate.</li>
</ul>
<p><span style="color: #ffffff">..</span></p>
<p>To read some of the answers to the questions, as commented by Barry Burke on the <a href="http://storagenerve.com/2009/12/09/fast-features-drawbacks-applications-and-some-questions/"  target="_blank">StorageNerve Blog</a></p>
<p>FAST is a bit of a new subject for me. Any experts please feel free to correct me if my understanding of FAST is incorrect at any level.</p>
<p>Stay tuned for a series of FAST posts over the next few days talking about various topics and how FAST plays within those areas.</p>
<div id="crp_related"><h3>You might also want to read these other posts...</h3><ul><li><a href="http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/"  rel="bookmark" class="crp_title">After all, FAST makes a debut</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/enhancements-emc-symmetrix-vmax-systems-coming/"  rel="bookmark" class="crp_title">Enhancements to EMC Symmetrix V-Max Systems coming!!</a></li><li><a href="http://gestaltit.com/all/tech/storage/stephen/emc-v-max-fast-coming-in-december-%e2%80%a6-and-2010/"  rel="bookmark" class="crp_title">EMC V-Max FAST: Coming in December … And 2010!</a></li><li><a href="http://gestaltit.com/all/tech/storage/martin/google-fast-infrastructure/"  rel="bookmark" class="crp_title">Google for the Infrastructure</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/symmetrix-file-system-sfs/"  rel="bookmark" class="crp_title">Symmetrix File System (SFS)</a></li></ul></div><script src="http://feeds.feedburner.com/~s/sfoskett?i=http://gestaltit.com/all/tech/storage/devang/fast-features-drawbacks-applications-and-some-questions/" type="text/javascript" charset="utf-8"></script><hr />
<p><small>© Devang for <a href="http://gestaltit.com">Gestalt IT</a>, 2009. |
<a href="http://gestaltit.com/all/tech/storage/devang/fast-features-drawbacks-applications-and-some-questions/">FAST: Features, Drawbacks, Applications and some Questions</a>
<br/>
Read more posts categorized as <a href="http://gestaltit.com/category/all/tech/storage/" title="View all posts in Storage" rel="category tag">Storage</a><br/>
</small></p>]]></content:encoded>
			<wfw:commentRss>http://gestaltit.com/all/tech/storage/devang/fast-features-drawbacks-applications-and-some-questions/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>After all, FAST makes a debut</title>
		<link>http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/</link>
		<comments>http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/#comments</comments>
		<pubDate>Thu, 10 Dec 2009 18:00:26 +0000</pubDate>
		<dc:creator>Devang Panchigar</dc:creator>
				<category><![CDATA[Storage]]></category>
		<category><![CDATA[Tech]]></category>
		<category><![CDATA[5874]]></category>
		<category><![CDATA[Atmos]]></category>
		<category><![CDATA[Automated]]></category>
		<category><![CDATA[Celerra]]></category>
		<category><![CDATA[Centera]]></category>
		<category><![CDATA[CLARiiON]]></category>
		<category><![CDATA[CLI]]></category>
		<category><![CDATA[CX4]]></category>
		<category><![CDATA[Data Movement]]></category>
		<category><![CDATA[Dynamic Cache Partitioning]]></category>
		<category><![CDATA[EMC]]></category>
		<category><![CDATA[FAST]]></category>
		<category><![CDATA[Fibre]]></category>
		<category><![CDATA[flash]]></category>
		<category><![CDATA[Fully Automated Storage Tiering]]></category>
		<category><![CDATA[Navisphere Analyzer]]></category>
		<category><![CDATA[Navisphere Quality Service manager]]></category>
		<category><![CDATA[NS]]></category>
		<category><![CDATA[Rainfinity file management / VE]]></category>
		<category><![CDATA[Rainfinity File management appliance]]></category>
		<category><![CDATA[Release 29]]></category>
		<category><![CDATA[SATA]]></category>
		<category><![CDATA[SSD]]></category>
		<category><![CDATA[Symcli]]></category>
		<category><![CDATA[Symmetrix Management Console]]></category>
		<category><![CDATA[Symmetrix Optimizer]]></category>
		<category><![CDATA[symmetrix performance analyzer]]></category>
		<category><![CDATA[symmetrix priority controls]]></category>
		<category><![CDATA[V-Max]]></category>

		<guid isPermaLink="false">http://gestaltit.com/?p=1940</guid>
		<description><![CDATA[Truly this was one of the most awaited products of 2009 from EMC after the initial announcement by EMC back in April 2009 along with the release of Symmetrix V-Max. Along with FAST, EMC has also introduced some new enhancements to the EMC Symmetrix V-Max, Clariion CX4 and Celerra NS platforms. Currently FAST will be available on the above 3 platforms at debut and will provide automated storage tiering “in-the-box” for Symmetrix V-Max, “in-the-box” for Clariion CX4 and “out-of-box” for Celerra NS platforms.]]></description>
			<content:encoded><![CDATA[<p><strong> </strong></p>
<p>So EMC has proved critics like me wrong and have introduced EMC <strong>FAST (Fully Automated Storage Tiering)</strong> as an offering in Dec 2009. There were many skeptics like me that saw this product release being stalled because of various reasons, <a href="../2009/12/03/fast-miles-and-miles-away/">here.</a></p>
<p><strong> </strong></p>
<div class="mceIEcenter">
<dl>
<dt><strong><strong><a href="http://storagenerve.com/wp-content/uploads/2009/12/FAST.jpg" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/FAST.jpg" alt="FAST (Fully Automated Storage Tiering)" width="229" height="240" /></a></strong></strong></dt>
<dd>FAST (Fully Automated Storage Tiering)</dd>
</dl>
</div>
<p><strong> </strong></p>
<p>Truly this was one of the most awaited products of 2009 from EMC after the initial announcement by EMC back in April 2009 along with the release of Symmetrix V-Max.</p>
<p>I have dedicated a separate deep-dive section for EMC FAST on the StorageNerve Blog, <a href="../deepdive/emc/fast/">here</a></p>
<p>Along with FAST, EMC has also introduced some new<strong> </strong>enhancements<strong> </strong>to the EMC Symmetrix V-Max, Clariion CX4 and Celerra NS platforms. Currently FAST will be available on the above 3 platforms at debut and will provide automated storage tiering <strong>“in-the-box” </strong>for Symmetrix V-Max, <strong>“in-the-box”</strong> for Clariion CX4 and <strong>“out-of-box”</strong> for Celerra NS platforms.</p>
<p>As expected EMC has not made this feature free but rather offers a pricing model based on bundled software. FAST will be an available feature within <strong>ATSM: Advanced Tiering Storage Management</strong> bundle and will be charged based on <strong>RAW Capacity of the Array</strong> (Symmetrix, Clariion and Celerra)</p>
<p>FAST will not be supported on EMC DMX-4 and Clariion CX3. In essence FAST is only compatible with <strong>EMC Symmetrix V-Max Enginuity Microcode 5874.xxx.xxx</strong> and<strong> Clariion CX4 Flarecode Release 29</strong>.</p>
<p>FAST is a software only feature and integrates with existing hardware / software on the associated platforms.</p>
<p>The following are some of the features FAST will support at GA on the EMC Symmetrix V-Max, Clariion CX4 and Celerra NS platforms.</p>
<p><strong>EMC Symmetrix V-Max</strong></p>
<p><strong> </strong></p>
<p style="text-align: center">
<div class="mceIEcenter">
<dl>
<dt><a href="http://storagenerve.com/wp-content/uploads/2009/12/V-Max-data-movement.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/V-Max-data-movement-231x300.png" alt="Symmetrix V-Max Data Movement" width="231" height="300" /></a></dt>
<dd>Symmetrix V-Max Data Movement</dd>
</dl>
</div>
<p><strong> </strong></p>
<ul>
<li>Volume / LUN based data movement (Automated Storage Tiering) for open systems and CKD &#8211; mainframe volumes.</li>
</ul>
<ul>
<li>Management of FAST through Symmetrix Management Console or SymCLI</li>
</ul>
<ul>
<li>Data Movement can be accomplished between FLASH, fibre channel and SATA drives within the V-Max platform. Data can move in any direction and on any type of the drives based on policy.</li>
</ul>
<ul>
<li>Data movement within a single frame or serial number only.</li>
</ul>
<ul>
<li>FAST suite can be purchased as a standalone software suite but will be available at a discounted price based on a bundled option with Symmetrix Optimizer, DCP: Dynamic Cache Partitioning and SPC: Symmetrix Priority Controls.</li>
</ul>
<ul>
<li>Symmetrix Performance Analyzer is not required for FAST to operate on the Symmetrix V-Max platform. <span style="text-decoration: line-through"><br />
</span></li>
</ul>
<p><strong>EMC Clariion CX4</strong></p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<div class="mceIEcenter">
<dl>
<dt><strong><strong><a href="http://storagenerve.com/wp-content/uploads/2009/12/Clariion-data-movement.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/Clariion-data-movement-144x300.png" alt="Clariion CX4 Data Movement" width="144" height="300" /></a></strong></strong></dt>
<dd>Clariion CX4 Data Movement</dd>
</dl>
</div>
<p><strong> </strong></p>
<ul>
<li>LUN based data movement (Automated Storage Tiering)</li>
</ul>
<ul>
<li>Management of FAST will be enabled through CLI only. Not supported as an integrated part of Navisphere today.</li>
</ul>
<ul>
<li>Will work with Flarecode Release 29 (Clariion CX4) only.</li>
</ul>
<ul>
<li>Unlike the Symmetrix, the automated data movement will only be supported between fibre channel drives to FLASH or fibre channel drives to SATA. There is no automation related to data movement from FLASH to fibre channel or FLASH to SATA or SATA to FLASH or SATA to fibre Channel drives.</li>
</ul>
<ul>
<li>Data movement within a single frame or serial number only.</li>
</ul>
<ul>
<li>FAST suite can be purchased as a standalone software suite but will be available at a discounted price based on bundled option with Navisphere Analyzer and NQSM: Navisphere Quality Service Manager.</li>
</ul>
<ul>
<li>Navisphere Analyzer is required for FAST to operate.</li>
</ul>
<p><strong>EMC Celerra platform</strong></p>
<p><strong> </strong></p>
<div class="mceIEcenter">
<dl>
<dt><strong><strong><a href="http://storagenerve.com/wp-content/uploads/2009/12/Celerra-in-box-movement.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/Celerra-in-box-movement-121x300.png" alt="Celerra in the box data movement" width="121" height="300" /></a></strong></strong></dt>
<dd>Celerra in the box data movement</dd>
</dl>
</div>
<p><strong> </strong></p>
<p><strong> </strong></p>
<p><strong> </strong></p>
<div class="mceIEcenter">
<dl>
<dt><strong><strong><a href="http://storagenerve.com/wp-content/uploads/2009/12/Celerra-out-of-box-movement.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/Celerra-out-of-box-movement-300x288.png" alt="Celerra in the box and out of box data movement" width="300" height="288" /></a></strong></strong></dt>
<dd>Celerra out of box data movement</dd>
</dl>
</div>
<p><strong> </strong></p>
<ul>
<li>File based data movement (Automated Storage Tiering)</li>
</ul>
<ul>
<li>Management of FAST can be accomplished through Rainfinity file management appliance GUI or CLI. Customers also have an option to purchase Rainfinity File management/VE (Virtual Appliance), which has some limitations.</li>
</ul>
<ul>
<li>Data movement can be enabled to another tier “in-the-box” or to another Celerra or Centera or Atmos.</li>
</ul>
<ul>
<li>Celerra FAST is most interesting as it enables out the system data movement, like to another Celerra or Centera or Atmos.</li>
</ul>
<ul>
<li>FAST suite can be purchased as a standalone software suite but will be available at a discounted price based on a bundled option with Rainfinity File Management Appliance or Rainfinity File Management /VE.</li>
</ul>
<p>Based on EMC heat index charts, a before and after picture of a FAST implementation would look like this.</p>
<div class="mceIEcenter">
<dl>
<dt><a href="http://storagenerve.com/wp-content/uploads/2009/12/FAST-implementation1.png" ><img src="http://storagenerve.com/wp-content/uploads/2009/12/FAST-implementation1.png" alt="FAST Implementation" width="544" height="190" /></a></dt>
<dd>FAST Implementation</dd>
</dl>
</div>
<p><strong>A FAST implementation video</strong></p>
<p style="text-align: center">
<p style="text-align: center">
<p>Here is a <a href="http://gestaltit.com/featured/top/gestalt/emc-unified-platform-storage-tiering/" >post</a>, back from August 2009 on Gestalt IT describing how EMC’s Unified Storage vision and federation may work. It is good to see, some of those things come to fruition now, and at least FAST with Celerra proves it.</p>
<p>Stay tuned for a series of FAST posts over the next few days talking about various other topics and how FAST plays within those areas.</p>
<div id="crp_related"><h3>You might also want to read these other posts...</h3><ul><li><a href="http://gestaltit.com/all/tech/storage/devang/fast-features-drawbacks-applications-and-some-questions/"  rel="bookmark" class="crp_title">FAST: Features, Drawbacks, Applications and some Questions</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/enhancements-emc-symmetrix-vmax-systems-coming/"  rel="bookmark" class="crp_title">Enhancements to EMC Symmetrix V-Max Systems coming!!</a></li><li><a href="http://gestaltit.com/featured/top/gestalt/emc-unified-platform-storage-tiering/"  rel="bookmark" class="crp_title">EMC’s Unified Platform and Storage Tiering</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/emc-symmetrix-vmax-supported-drive-type/"  rel="bookmark" class="crp_title">EMC Symmetrix V-Max: Supported drive type</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/symmetrix-file-system-sfs/"  rel="bookmark" class="crp_title">Symmetrix File System (SFS)</a></li></ul></div><script src="http://feeds.feedburner.com/~s/sfoskett?i=http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/" type="text/javascript" charset="utf-8"></script><hr />
<p><small>© Devang for <a href="http://gestaltit.com">Gestalt IT</a>, 2009. |
<a href="http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/">After all, FAST makes a debut</a>
<br/>
Read more posts categorized as <a href="http://gestaltit.com/category/all/tech/storage/" title="View all posts in Storage" rel="category tag">Storage</a>, <a href="http://gestaltit.com/category/all/tech/" title="View all posts in Tech" rel="category tag">Tech</a><br/>
</small></p>]]></content:encoded>
			<wfw:commentRss>http://gestaltit.com/all/tech/storage/devang/after-all-fast-makes-a-debut/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>EMC AX4 Platform</title>
		<link>http://gestaltit.com/all/tech/storage/devang/emc-ax4-platform/</link>
		<comments>http://gestaltit.com/all/tech/storage/devang/emc-ax4-platform/#comments</comments>
		<pubDate>Tue, 28 Jul 2009 13:00:23 +0000</pubDate>
		<dc:creator>Devang Panchigar</dc:creator>
				<category><![CDATA[All]]></category>
		<category><![CDATA[Storage]]></category>
		<category><![CDATA[AX4-5F]]></category>
		<category><![CDATA[AX4-5FSC]]></category>
		<category><![CDATA[AX4-5i]]></category>
		<category><![CDATA[AX4-5iSC]]></category>
		<category><![CDATA[CLARiiON]]></category>
		<category><![CDATA[Drive Capacity]]></category>
		<category><![CDATA[EMC AX4]]></category>
		<category><![CDATA[Ionix]]></category>
		<category><![CDATA[mirrorview]]></category>
		<category><![CDATA[Navisphere Analyzer]]></category>
		<category><![CDATA[Navisphere Express]]></category>
		<category><![CDATA[Navisphere Manager]]></category>
		<category><![CDATA[Navisphere QoS]]></category>
		<category><![CDATA[PowerPath]]></category>
		<category><![CDATA[RecoverPoint]]></category>
		<category><![CDATA[Replication Manager]]></category>
		<category><![CDATA[SANCopy]]></category>
		<category><![CDATA[SnapView]]></category>
		<category><![CDATA[Supported Host]]></category>
		<category><![CDATA[Technology]]></category>
		<category><![CDATA[thin provisioning]]></category>

		<guid isPermaLink="false">http://storagenerve.com/?p=616</guid>
		<description><![CDATA[Previously I had explained the evolution of the EMC Clariion Technology including the AX products and the flare code that is associated with the success of this platform. This post describes the 4 available models within the AX4 Platform and the naming conventions used.
]]></description>
			<content:encoded><![CDATA[<p>On a few reader request, here is a blog post on EMC AX4 technology.</p>
<p>Previously in one of the post on StorageNerve, I had explained the evolution of the EMC Clariion Technology including the AX products and the flare code that is associated with the success of this platform, <a href="http://storagenerve.com/2009/01/06/emc-clariion-flare-code-operating-environment/" >to read the blog post.</a></p>
<p><strong>The following are the 4 available models within the AX4 Platform; the naming conventions will explain it further. </strong></p>
<ul>
<li><strong>AX4-5F</strong> (Fiber Channel Host Connect)</li>
<li><strong>AX4-5FSC</strong> (Fiber Channel Host Connect, Single RAID Controller)</li>
<li><strong>AX4-5i</strong> (iSCSI Host Connect)</li>
<li><strong>AX4-5iSC</strong> (iSCSI Host Connect, Single Raid Controller)</li>
</ul>
<p><strong>Drives per DAE (Drive Array Enclosure): <span style="font-weight: normal">12</span></strong></p>
<p><strong>Maximum DAE’s (Drive Array Enclosure) supported per System: <span style="font-weight: normal">4</span></strong></p>
<p><strong>DPE (Disk Processor Enclosure): <span style="font-weight: normal">12 drive per DPE</span></strong></p>
<p><strong> </strong></p>
<p><strong>Maximum Drives Supported per System: <span style="font-weight: normal">60</span></strong></p>
<p><strong>Minimum Drives Supported per System: <span style="font-weight: normal">4 Drives including the Flare Drives (Flare code resides on the 1<sup>st</sup> 4 drives of the DPE, with do not remove stickers).</span></strong></p>
<p><strong>Naming Convention for Drives:</strong></p>
<ol>
<li>Bus</li>
<li>Enclosure</li>
<li>Drive No</li>
</ol>
<p>Possible Options</p>
<ul>
<li>Bus 0 and 1</li>
<li>Enclosure 1, 2, 3, 4 (DPE becomes enclosure 0)</li>
<li>Drive 0 through 11 (12 Drives total)</li>
</ul>
<p>B0_E3_D11 becomes Bus 0, Enclosure 3 and Drive 12</p>
<p><strong>The following are the disk drives that are supported with the AX4 Platforms. </strong></p>
<table border="0" cellspacing="5" cellpadding="5">
<tbody>
<tr style="text-align: center">
<th>Capacity</th>
<th>Speed</th>
<th>Type</th>
</tr>
<tr style="text-align: center">
<th>1TB</th>
<td>7.2K</td>
<td>SATA</td>
</tr>
<tr style="text-align: center">
<th>750GB</th>
<td>7.2K</td>
<td>SATA</td>
</tr>
<tr style="text-align: center">
<th>450GB</th>
<td>15K</td>
<td>SAS</td>
</tr>
<tr style="text-align: center">
<th>400GB</th>
<td>15K</td>
<td>SAS</td>
</tr>
<tr style="text-align: center">
<th>400GB</th>
<td>10K</td>
<td>SAS</td>
</tr>
<tr style="text-align: center">
<th>300GB</th>
<td>15K</td>
<td>SAS</td>
</tr>
<tr style="text-align: center">
<th>146GB</th>
<td>15K</td>
<td>SAS</td>
</tr>
</tbody>
</table>
<p style="text-align: left">As you notice above, only SAS and SATA drives are usable on an AX4 system with no support for FC or EFD’s.</p>
<p><strong>Supported RAID Types with AX4 Systems</strong></p>
<ul>
<li>RAID 0, RAID 0+1, RAID 3 and RAID 5 Technologies.</li>
<li><strong><span style="color: #ff0000">CORRECTION: </span></strong>RAID 6 is now supported on AX-4 Platforms starting release 23 (Navisphere Express).</li>
</ul>
<p><strong> </strong></p>
<p><strong>Supported Software on the AX4 Systems</strong></p>
<ul>
<li>Navisphere Express included</li>
<li>Navisphere Manager (Only with 2 Service Processors)</li>
<li>Navisphere QoS</li>
<li>Navisphere Analyzer</li>
<li>SnapView</li>
<li>MirrorView/S and /A</li>
<li>SANCopy</li>
<li>Ionix Control Center plug-in</li>
<li>PowerPath</li>
<li>RecoverPoint/SE and CDP/CRR</li>
<li>Replication Manager</li>
</ul>
<p><strong>Host Type Supported</strong></p>
<ul>
<li>Windows 2000/2003/2008</li>
<li>Linux</li>
<li>Solaris</li>
<li>HP-UX</li>
<li>AIX</li>
<li>VMware</li>
</ul>
<p><strong>Some very important characteristics of the AX4 Platforms</strong></p>
<ul>
<li>Very cost effective</li>
<li>Completes in the SMB space with low end IBM and HP Storage</li>
<li>Scales upto 60TB RAW Storage</li>
<li>Supports upto 64 Host systems connected</li>
<li>1GB Cache per Service Processor, 2GB max for dual processors.</li>
<li>4GB FC connectivity to host (fiber ports to switch / host)</li>
<li>You can run it with a single controller or dual controllers</li>
<li>iSCSI Support</li>
<li>SAS and SATA drives are supported</li>
<li>All Clariion Software supported</li>
<li>SPS (single included): Standby Power Supply – Battery allows the cache to destage during a forced shutdown resulting in no data loss</li>
<li>MetaLUN Technology supported</li>
<li>Virtual LUN Technology supported</li>
<li>Snaps and Clones supported</li>
<li>Supports Flare Release 23, 26 and 28.</li>
</ul>
<div id="crp_related"><h3>You might also want to read these other posts...</h3><ul><li><a href="http://gestaltit.com/all/tech/storage/devang/emc-clariion-systems-global-hot-spares-proactive-hot-spares/"  rel="bookmark" class="crp_title">EMC Clariion Systems: Global Hot Spares &amp; Proactive Hot Spares</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/emc-clariion-raid6-requirements-limitations/"  rel="bookmark" class="crp_title">EMC Clariion RAID-6 requirements and limitations</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/emc-clariion-10-years/"  rel="bookmark" class="crp_title">EMC CLARiiON Systems since the Data General Acquisition (10 Years)</a></li><li><a href="http://gestaltit.com/all/tech/virtualization/simon/vmware-hot-add-memorycpu-support/"  rel="bookmark" class="crp_title">VMware Hot-Add Memory/CPU Support</a></li><li><a href="http://gestaltit.com/all/tech/storage/devang/enterprise-flash-drives-efd-emc-symmetrix-vmax-systems/"  rel="bookmark" class="crp_title">Enterprise Flash Drives (EFD) on EMC Symmetrix V-Max Systems</a></li></ul></div><script src="http://feeds.feedburner.com/~s/sfoskett?i=http://gestaltit.com/all/tech/storage/devang/emc-ax4-platform/" type="text/javascript" charset="utf-8"></script><hr />
<p><small>© Devang for <a href="http://gestaltit.com">Gestalt IT</a>, 2009. |
<a href="http://gestaltit.com/all/tech/storage/devang/emc-ax4-platform/">EMC AX4 Platform</a>
<br/>
Read more posts categorized as <a href="http://gestaltit.com/category/all/" title="View all posts in All" rel="category tag">All</a>, <a href="http://gestaltit.com/category/all/tech/storage/" title="View all posts in Storage" rel="category tag">Storage</a><br/>
</small></p>]]></content:encoded>
			<wfw:commentRss>http://gestaltit.com/all/tech/storage/devang/emc-ax4-platform/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

